There are 5 wiring holes on the back, which are L1, S0, S1, L, and N. Among them, the load line, such as lights or socket, connect to L1, the live line connects to L, and the neutral line connects to N.
There are three connection methods for S0 and S1: 1. Connect them to the two ends of the external switch respectively; 2. Connect S0 to one end of the external switch; S1 is idle. The other end is connected to the fire line; 3. If there is no external switch, you don't need to connect it. The first two connection methods can realize the control of the Single Switch Module T1 by the external switch.
There are three ways to enter the networking status:
First, by using Single Switch Module T1 (With Neutral) in combination with a wireless switch, it is very easy to realize double control / multiple control. The wireless switch can be placed at most positions of your home to coordinately control the Single Switch Module T1 (With Neutral);
If the traditional double-control switch has been installed, Single Switch Module T1 (With Neutral) can be placed in the controlled device or in the cassette near the device . The original switch connects to from the line end of the load wire to S0 wiring hole, S1 is not connected, L1 / L wiring hole is connected normally, and the original double control line can be maintained to realize double control.